duty

Surgical Staplers,Circular Staplers

* Esophagectomy,Gastrectomy,Small intesting and

Colon Excision Operation,Rectum low antrior resection

Linear Cutter Stapler,Linear Stapler

* General Surgery, Chest Surgery,Gynecology
and the parenchyma Excision,transection,reforger and anastomose of pediatric Operation.

 

About Navigation

.
Hemorrhoids Stapler

Disposable Hemorrhoids Stapler(PPH)

For Prolapse and Hemorrhoids(PPH)

Dis PPH link

Disposable use,avoid the possibility of cross-infection

PPH links

Can adjust the height according to requirement

Hemorrhoids Stapler(pph) Link

Have large contain place,preventing outflow of parenchyma

PPH stapler Links

Sew with reasonable nail number,reduce the bleeding after operation

Stapler PPH

Have complete assistant device,cooperate with the operation perfectly

                TECHNICAL SPECIFICATIONS


DISPOSABLE HEMORRHOIDS STAPLER(TITANIUM)


(HAIDA-CHINA-MODEL:HYG-32,HYG-33,HYG-34)


Features: -Automatic machine,round head cutter containning titanium knife and staples,surgical safety locking device body,squeeze handle,adjustment knob,padded cutting knife ring.

        - Sterilized by EO (Ethylene Oxide).

          -The reasonable arrangement of the pin position reduces bleeding after cutting.

          -The rectal mucosa is cut according to the correction of mucosal prolapse.

          -The cutting head has a wide design with enough space for manipulation.

          -Construction materials: Anvil head:Stainless steel,handel: Stainless steel,magazine: ABS plastic,adjustment button: ABS Plastic,attached accessories: ABS/PC Plastic,blade:Stainless steel.

          -The suture position can withstand pressure>3.6Kpa and does not leak or tear.

          -There are markings on the cartridge to clearly indicate the level of insertion


Pack:

-Product set includes: 01 main machine;Magazine: 1 set; Anorectal instrument: 1 piece; Anal-rectal dilator: 1 piece;Mucosal dilator and suture device: 1 piece;Suture hook tool: 1piece


Specifications table: 

Model
Incision Dia   (mm)
Dia (mm)
Number of Staples 
 Staple height Open (mm)
Staple Height Close(mm)
HYG-32
22
32
28
 3.8mm
0.75-1.5
HYG-33
24
33
30
 4.0mm
0.75-1.5
HYG-34
25
33
32
 4.2mm
0.75-1.5


 

Circular Staplers for Rectal Prolapse and Hemorrhoids(Circular Stapler For PPH)


1.Function

Cut and anastomose prolaposed mucosa tissue around the anal canal and rectum.
Step to use
Using three clamps to support three points where prolapsed mucosa is less and ectropion mucosa is light, then lead the anal retractor and anal speculum into anus.
The anal retractor and anal speculum in anus will recover the prolapsed hemorrhoid or the mucosa of the anal canal. Remove the anal retractor to let the prolapsed mucosa be in the anal speculum.
Feed the sutural piece through the anal speculum .The suture should be over 3-4 cm far from the dentate line adjusted according to the degree degree of prolapes. By turning the sutural piece, the suture around the whole anal canal can be finished.
Feed the anastomat to make the nail retainer come to the upper end of the purse, then knot the suture on the central rod of the device.
With the aid of the barbed needle, pull out the tail end of the suture from the line-drawn hole of the anastomat.
Draw the purse suture suitably to put the prolapsed mucosa into the cavity of the head of the anastomat and close it. The red dial indication should entered into the green zone and it is suggested to enter into the bottom of the green zone. Open the safety, trigger and cut prolapsed mucosa in the cavity.
To help stop bleeding, keep the closed state of the anastomat for least 30 seconds after triggering. Turn out the anastomat counterclockwise gently for 2-3 turn, and return it back from the part of anal canal. And the operation is finished.

 

2.Note

The suture should be over 4cm far from the denbtate line. And the anastomatic port should be over 2cm,because the low location will cause bleed after the operation, while the high location cause unconspicuous effect. The lowest position of sutured purse should under mucosa. If too shallow, it is easy to rive the mocosa, and too deep, easy to hurt the sphincter.
The ligated line can not be too tight, or it will affect pulling out the line-drawn.
After the operation, check the anastomotic port by means of the sutural piece. If hemorrhagic spot is found, it should be sutured to stop bleeding.

3.How PPH Works ?(Click me)